Cavitation and Air Entrainment Aren't the Same

Nov 10
2 min read

Updated: 22 hours ago

Your pump sounds like it’s pumping gravel.


The tech says, “it’s cavitating.” Maybe. Or maybe it’s sucking air. They sound alike but they're different and they can cause different problems.


Cavitation is the liquid boiling. When pressure at the impeller drops below the fluid’s vapor pressure, vapor bubbles form. They then collapse violently as they reach higher pressure. That collapse pits the vanes near the eye. The root cause is that the inlet pressure is too low.


Air entrainment is gas (that was never liquid) being mixed into the liquid you're pumping. It gets in through a leaking suction joint, a shaft seal or packing under vacuum, a vortex in a low tank, or a return line splashing into the reservoir.


Air doesn’t stay in the pump, either. Vapor bubbles from cavitation collapse right at the impeller and turn back into liquid, but air bubbles travel. They collect at high points in the piping until the pocket grows large enough to break loose and the slug pushes through the system. Then it builds again, over and over. If that line has sensors, they see every slug. Flow meters read erratically, conductivity and concentration readings jump, pressure swings, and you get nuisance alarms and failed steps that look like an instrument problem.


The sensors aren’t the problem. The air is.


Typical behavior: Everything looks fine, but the sensor has some kind of spike every few minutes. That's what happens when enough air collects at a high point to get pushed out... it travels through the line as a slug of air. Then it starts collecting again.


How to tell them apart on the floor:

→ Watch the gauges. Fluctuating discharge pressure or amps, or a pump that loses prime, points to air. Cavitation is usually a steady crackle.

→ Look for bubbles in a sight glass, foam in the tank, or a swirl at the suction inlet.

→ Check suction joints on the inlet side of the pump with the pump off, then on. A joint that drips when the pump is off and goes dry when it runs isn’t fixed. It’s sucking air.

→ Pull the impeller. Cavitation leaves pitting on the vanes near the eye. Air rarely does.


The fixes don’t overlap:

Cavitation → raise the tank level, clean the strainer, shorten or upsize the suction line, lower the temperature, or run closer to the best efficiency point.

Air → seal the leaks, increase submergence, add a vortex breaker, relocate the returns, and vent the high points.

Calling everything “cavitation” means you’ll replace an impeller and leave the air leak that killed it. Then you’ll be chasing sensor faults for months.


Diagnose the mechanism, not the sound.


Does your pump sound like it’s moving gravel, even after a repair?

Mac Davis provides hands-on industrial maintenance troubleshooting through 180 IMT.


Does every shift know what to check when a pump sounds wrong?

180 OPEX helps manufacturers set clear priorities and follow them across shifts.