Maintenance Detective: Manifold Air Leak
A bottle line has an 8-station valve manifold running the cylinders on the reject and diverter section: two reject pushers, a lane diverter, a bottle stop, and a few clamps. An issue came up on second shift because the operator reported that the line was intermittently rejecting the bottle after a "low fill" and it's doing it on both rejectors. The tech noticed a constant hiss from the manifold and couldn't localize the leak. The tech did the following tests: Soap-tests ever

Mac Davis
4 min read


Maintenance Detective: Pneumatic Cylinders
A messy powder filler is fed by a pair of pneumatic indexing cylinders. They gate bottles into the filler one at a time. But there is a problem: When you start the line it runs perfectly. Crisp, fast index strokes. About two minutes in, the cylinders start getting lazy. Strokes slow down. Bottles start arriving late. Then the indexers barely move and the filler starves. Stop the line for a bit. Restart. Perfect again... for about two minutes. Over and over. All shift. You hav

Mac Davis
2 min read